'CR200 Series Datalogger 'Sample program to measure an ECI-1 Concrete Corrosion Sensor once a month on the 15th day 'Date: February 6, 2006 'Program author: Robert Herfst, Campbell Scientific (Canada) Corp. 'Wiring: ' Blue - C1/SDI-12 ' Black - G ' White - Battery + Public Batt_volt Public Result(5) Public Flag1 Public today Public Counter Alias Result(1) = Chloride Alias Result(2) = GSTAT Alias Result(3) = PSTAT Alias Result(4) = Temp Alias Result(5) = OCP 'Define Data Tables DataTable (ECI_Data,1,0) Minimum (1,batt_volt,0,0) Sample 5,Result(1) EndTable 'Main Program BeginProg Scan (1,min) Battery (Batt_volt) 'Measure sensor once a month on the 15th day. RealTime (today,3) If today=15 Then Counter=Counter+1 If Counter=1 Then SDI12Recorder (Chloride,0C!,1.0,0) CallTable ECI_Data EndIf If today=16 Then Counter=0 NextScan EndProg